Home > Drivers Ibm > Drivers Ibm System X3400 M3

Drivers Ibm System X3400 M3

The server supports up to two processors. The System x3400 M3 server supports optional spare DIMMs, memory mirroring, and RAID-0, RAID-1, and RAID-1E support standard with optional RAID-5, RAID-6, RAID-10, and RAID-50 available. This is as much as 80% less power than a 2.5-inch HDD would use, with a corresponding reduction in heat output that further improves the overall bottom line. The table also shows which server models have each processor standard. More about the author

Ethernet Integrated two Gigabit Ethernet ports. Optical drives Part number Featurecode Description Maximumsupported Standard modelswhere used None* 4154 IBM HH DVD-ROM 56x, 58x, A2x, A4x, B2x, B4x,C2x, D2x, E4x, E6x, F2x, 74x, E1x, E2x, E3x, 22x, 24x, Hot-swap components Hard drives, power supplies, fans. The following table lists the RAID controllers and additional options used for internal disk storage of the x3400 M3 server.

The ServeRAID M5025 SAS/SATA Controller has the following specifications: Two Mini-SAS external connectors Supports RAID levels 0, 1, 5, 10, and 50 Supports RAID 6 and 60 with the optional M5000 The server offers memory mirroring for redundancy in the event of a non-correctable memory failure. System planar: Slot 1: PCIe 2.0 x8, full height, half length Slot 2: PCIe 2.0 x16 (x8 wired), full height, full length Slot 3: PCIe 2.0 x8 (x4 wired), full height, Rate & Provide Feedback Rating No Rating Your Name (optional) Your Email Address (optional) Comment (optional) Submit Feedback Thank you for your feedback.

The server supports up to two redundant hot-swap 920 W AC power supplies. to 5:00 p.m. Server Error 403 - Forbidden: Access is denied. https://www.suse.com/partners/ihv/pdf/System_Certification_Policies.pdf For more information regarding the specific test configuration, please contact: IBM For support regarding this specific configuration, please visit: www.ibm.com 559649

The following table lists the virtualization options. Industry-standard AES NI support for faster, stronger encryption. IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. Integrated IPMI 2.0 support alerts IBM Systems Director to anomalous environmental factors, such as voltage and thermal conditions.

Figure 1 shows the IBM® System x3400 M3. If this option is used, then only one UltraSlim optical drive can be installed. The power supply option includes three fans however these fans are only for use with the x3500 M3. Optionally, the IMM also provides a virtual presence capability for remote server management capabilities.

Table 15. try here Systems management UEFI, IBM Integrated Management Module (IMM), Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, IBM Systems Director* and IBM Systems Director Active Energy Manager™, IBM ServerGuide. The ServeRAID BR10il v2 SAS/SATA Controller has the following specifications: One Mini-SAS internal connector Supports RAID levels 0, 1, and 1E 3 Gbps throughput per port Based on the LSI 1064E However, not all configurations offer 5.25" HH bays as shown in Figure 5.

Standard models Model† Intel Processor*(2 maximum) RAM Diskcontroller Disk bays(std/max) Disks Network Optical Power supply Models announced February 20117378/7379-A2x 1x E5603 4C 1.60 GHz4 MB 1066 MHz 1x 2 GB Integrated Disk backplanes are directly connected to the ports on the RAID controller. We provide service around the clock, every day, including IBM holidays. 9x5x4 hour A service technician is scheduled to arrive at your customer’s location within four business hours after remote problem One internal USB port for embedded hypervisor.

The slot form factors are as follows. Memory protection ECC, ChipKill (for x4-based memory DIMMs), memory mirroring, and memory sparing. Table 6. click site Power supplies Part number Feature code Description Maximum supported 44X0381 5056 IBM Redundant Power Supply for x3400/3500 2 (One power supply comesstandard with every model.) The power supply ships without a

Figure 2. Finally my PC got up to speed!" Melany Kim 7/18/2016Our main support OS are: Windows 7, Windows 7 64 bit, Windows 7 32 bit, Windows 10, Windows 10 64 bit, Windows Supports specific Quad-core Intel Xeon 5500 series processors via Configure-To-Order (CTO).

IBM Systems Director comes with a portfolio of tools, including IBM Systems Director Active Energy Manager, IBM Service and Support Manager, and others.

The two half-high drives in the table can be installed in any available 5.25" drive bays (Figure 5). Power supplies The server supports either one 670 W AC fixed power supply or up to two 920 W AC hot-swap redundant power supplies, providing N+N redundancy. Table 4. We provide service around the clock, every day, including IBM holidays. 24x7x4 hour A service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination

IBM Systems Director Active Energy Manager provides advanced power management features with actual real-time energy monitoring, reporting, and capping features. Video Matrox G200eV with 16 MB memory integrated into the IMM. Seven USB 2.0 ports available - two front, four rear, and one internal for an embedded hypervisor. Dimensions Width: 218 mm (8.6 in), depth: 767 mm (30.2 in), height: 440 mm (17.3 in) Weight Minimum configuration: 27.10 kg (59.7 lb), Maximum configuration: 37.85 kg (83.4 lb) * Effective

Intermix of SAS/SATA is supported. RAID support RAID 0, 1, 1E with ServeRAID BR10il v2 or M1015; RAID 0, 1, 5, 10, 50 with M5014 or M5015. These servers fit into business environments where tower configurations are required. Figure 4.

If an environmental condition exceeds a threshold or if a system component fails, the IMM lights LEDs to help you diagnose the problem, records the error in the event log, and In such a case, one cable is used to connect first EXP25xx or EXP3000 to the RAID controller, and every consecutive EXP unit is connected to the previous one by one These internal drives are installed in the 5.25" HH bays in the server. Express models The following table lists the region-specific Express models.

Limited warranty One-year (7378) or 3-year (7379) customer-replaceable unit and onsite limited warranty with 9x5/next-business-day response time. Optional solid-state drives (SSDs) use only 2 W of power per drive, compared to 9 - 10 W for 2.5-inch HDDs. Mixing 1.5 V and 1.35 V DIMMs in the same server is supported for Intel Xeon 5600 series processor-based systems. This 2-socket server provides a balance of performance, high availability, expansion capability and ease of management in a stable, long-life platform.

A complete setup solution, allowing adapter configuration functions to be moved into UEFI. From a service and support standpoint, IBM memory automatically assumes the IBM system warranty, and IBM provides service and support worldwide. Table 2.